Bønsvig-Stavreby Vandværk

Vandprøve analyse:

Prøveid: Prøvedato: Prøveudtagningssted: Formål: Omfang: Laboratorie: Journalnr.: Bemærkning:

454371 2006-03-06 09:00:00 Pr¿vehane p¿ vandv`r
Drikkevandskontrol, vandværk Normal kontrol + organisk mikroforurening ROVESTA Miljø I/S, Nykøbing Falster 30887601


Stof: Mængde: Min.: Max.: Målegrænse: Metode:

1,1,1-trichlorethan <0,020 µg/l GC/MS, Purge and trap

1,2-Dichlorethan <0,020 µg/l GC/MS, Purge and trap

2,4-Dichlorphenol <0,010 µg/l LC/MS

2,4-Dichlorphenoxyeddikesyre <0,010 µg/l LC/MS

2,6-Dichlorbenzamid <0,010 µg/l LC/MS

4-Chlor-2-methylphenol <0,010 µg/l LC/MS

Ammoniak+ammonium <0,010 mg/l DS 224

Atrazin <0,010 µg/l LC/MS

Bentazon <0,010 µg/l LC/MS

Benzen <0,020 µg/l GC/MS, Purge and trap

Chlorid 49,000 mg/l DS/EN ISO 10304-1

Coliforme bakterier ved 37grader. <1,000 antal/100 ml Colilert Quanti Tray

Cyanazin <0,010 µg/l LC/MS

Desethyl-atrazin <0,010 µg/l LC/MS

Desisopropyl-atrazin <0,010 µg/l LC/MS

Dichlobenil <0,010 µg/l GC/MS

Dichlorprop <0,010 µg/l LC/MS

Dimethoat <0,010 µg/l LC/MS

Dinitro-o-cresol <0,010 µg/l LC/MS

Dinoseb <0,010 µg/l LC/MS

Farve 0,000 Ikke oplyst Ikke oplyst

Fluorid 1,070 mg/l DS/EN ISO 10304-1

Hexazinon <0,010 µg/l LC/MS

Hydroxy-atrazin <0,010 µg/l LC/MS

Ikke flygtigt organisk kulstof 4,900 mg/l DS/EN 1484

Isoproturon <0,010 µg/l LC/MS

Jern <0,005 mg/l DS/EN ISO 11885

Kimtal ved 22 grader <1,000 antal/ml DS/EN ISO 6222

Kimtal ved 37 grader, PCA <1,000 antal/ml DS/EN ISO 6222

Konduktivitet 78,000 mS/m DS 288

MCPA <0,010 µg/l LC/MS

Mangan <0,005 mg/l ICP

Mechlorprop <0,010 µg/l LC/MS

Metamitron <0,010 µg/l LC/MS

Naphthalen <0,020 µg/l GC/MS, Purge and trap

Nitrat 4,050 mg/l DS 223

Nitrit 0,015 mg/l DS 222

Pendimethalin <0,010 µg/l LC/MS

Phosphor, total-P 0,010 mg/l DS 292

Simazin <0,010 µg/l LC/MS

Sulfat 8,200 mg/l DS/EN ISO 10304-1

Temperatur 8,000 grader C Ikke oplyst

Terbuthylazin <0,010 µg/l LC/MS

Termotolerante colibakterier <1,000 antal/100 ml Colilert Quanti Tray

Tetrachlorethylen <0,020 µg/l GC/MS, Purge and trap

Tetrachlormethan <0,020 µg/l GC/MS, Purge and trap

Toluen <0,020 µg/l GC/MS, Purge and trap

Trichlorethylen <0,020 µg/l GC/MS, Purge and trap

Trichlormethan <0,020 µg/l GC/MS, Purge and trap

m+p-Xylen <0,020 µg/l GC/MS, Purge and trap

o-Xylen <0,020 µg/l GC/MS, Purge and trap

pH 7,200 pH DS 287


Dit vandværk

Bønsvig-Stavreby Vandværk

Søparkvej 2

4720 Præstø

 

Mail: b-svand@b-svand.dk

Tlf.: 51706064

CVR 52427916


 

Vandets hårdhed

 

Vandet fra Bønsvig-Stavreby vandværk har en hårdhed på 17-19 dH